Reverse Osmosis – Model ES 10,000
AS / FU Series: 10000 – 20000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilised drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.
AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.
Tech Data | UO | ES 10000 |
Permeate flow rate | l/h | 10000 |
Min. salt rejection | % | 97 |
Recovery | % | 75 |
Operating pressure | bar | 10,0 |
Membrane element / number | | 8040 / 9 |
Voltage | V/Hz | 3 x 400/50 |
Motor power | kW | 7,5 |
Feedwater connection | DN | 50 |
Permeate/concentrate connection | DN | 50 / 32 |
Dosing point connection | R | ½" |
Conductivity range | μS/cm | 2 – 200 |
Min./max. feedwater pressure | bar | 2 / 6 |
Min./max. feedwater temperature | °C | 5 / 35 |
Max. ambient temperature | °C | 40 |
pH | | 3 – 11 |
Height | mm | 1,900 |
Width | mm | 3,900 |
Depth | mm | 800 |
Weight | kg | 900 |
Code no. | | 381 750 |
Reverse Osmosis – Model ES 12,000
AS / FU Series: 10000 – 20000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilised drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.
AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.
Tech Data | UO | ES 12000 |
Permeate flow rate | l/h | 12000 |
Min. salt rejection | % | 97 |
Recovery | % | 75 |
Operating pressure | bar | 9,0 |
Membrane element / number | | 8040 / 10 |
Voltage | V/Hz | 3 x 400/50 |
Motor power | kW | 7,5 |
Feedwater connection | DN | 50 |
Permeate/concentrate connection | DN | 50 / 50 |
Dosing point connection | R | ½" |
Conductivity range | μS/cm | 2 – 200 |
Min./max. feedwater pressure | bar | 2 / 6 |
Min./max. feedwater temperature | °C | 5 / 35 |
Max. ambient temperature | °C | 40 |
pH | | 3 – 11 |
Height | mm | 1,900 |
Width | mm | 4,900 |
Depth | mm | 800 |
Weight | kg | 1,000 |
Code no. | | 381 760 |
Reverse Osmosis – Model ES 15,000
AS / FU Series: 10000 – 20000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilized drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.
AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.
Tech Data | UO | ES 15000 |
Permeate flow rate | l/h | 15000 |
Min. salt rejection | % | 97 |
Recovery | % | 75 |
Operating pressure | bar | 9,5 |
Membrane element / number | | 8040 / 12 |
Voltage | V/Hz | 3 x 400/50 |
Motor power | kW | 11,0 |
Feedwater connection | DN | 65 |
Permeate/concentrate connection | DN | 65 / 50 |
Dosing point connection | R | ½" |
Conductivity range | μS/cm | 2 – 200 |
Min./max. feedwater pressure | bar | 2 / 6 |
Min./max. feedwater temperature | °C | 5 / 35 |
Max. ambient temperature | °C | 40 |
pH | | 3 – 11 |
Height | mm | 1,900 |
Width | mm | 4,900 |
Depth | mm | 800 |
Weight | kg | 1,100 |
Code no. | | 381 770 |
Reverse Osmosis – Model ES 18,000
AS / FU Series: 10000 – 20000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilized drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.
AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.
Tech Data | UO | ES 18000 |
Permeate flow rate | l/h | 18000 |
Min. salt rejection | % | 97 |
Recovery | % | 75 |
Operating pressure | bar | 9,5 |
Membrane element / number | | 8040 / 15 |
Voltage | V/Hz | 3 x 400/50 |
Motor power | kW | 11,0 |
Feedwater connection | DN | 65 |
Permeate/concentrate connection | DN | 65 / 50 |
Dosing point connection | R | ½" |
Conductivity range | μS/cm | 2 – 200 |
Min./max. feedwater pressure | bar | 2 / 6 |
Min./max. feedwater temperature | °C | 5 / 35 |
Max. ambient temperature | °C | 40 |
pH | | 3 – 11 |
Height | mm | 1,900 |
Width | mm | 5,900 |
Depth | mm | 800 |
Weight | kg | 1,300 |
Code no. | | 381 780 |
Reverse Osmosis – Model ES 20,000
AS / FU Series: 10000 – 20000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilised drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.
AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.
Tech Data | UO | ES 20000 |
Permeate flow rate | l/h | 20000 |
Min. salt rejection | % | 97 |
Recovery | % | 75 |
Operating pressure | bar | 9,0 |
Membrane element / number | | 8040 / 17 |
Voltage | V/Hz | 3 x 400/50 |
Motor power | kW | 11,0 |
Feedwater connection | DN | 65 |
Permeate/concentrate connection | DN | 65 / 50 |
Dosing point connection | R | ½" |
Conductivity range | μS/cm | 2 – 200 |
Min./max. feedwater pressure | bar | 2 / 6 |
Min./max. feedwater temperature | °C | 5 / 35 |
Max. ambient temperature | °C | 40 |
pH | | 3 – 11 |
Height | mm | 2,200 |
Width | mm | 4,900 |
Depth | mm | 800 |
Weight | kg | 1,500 |
Code no. | | 381 790 |