herco es range ro water filters

ES - SERIES 1

ES Range Reverse Osmosis

Reverse Osmosis – ES Series 1650 to 3300 l/ph

For desalination of hardness stabilised water with a salt content of < 1000 mg/l according to German drinking water regulations (free chlorine not detectable). With RO 1000 controller, high pressure pump, frequency controller, concentrate flushing device, connection set for manual cleaning device and preparation for installation of an antiscalant dosing unit.

For desalination of hardness stabilised water with a salt content of < 1000 mg/l according to German drinking water regulations (free chlorine not detectable). With RO 1000 controller, high pressure pump, frequency controller, concentrate flushing device, connection set for manual cleaning device and preparation for installation of an antiscalant dosing unit.

Tech DataUOES 1650
Permeate flow ratel/h1,650
Min. salt rejection%97
Recovery%75
Operating pressurebar10,0
Membrane element / number4040 / 6
VoltageV/Hz3 x 400/50
Motor powerkW2,2
Feedwater connectionDN32
Permeate/concentrate connectionDN25 / 25
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Min./max. feedwater pressurebar2 / 6
Min./max. feedwater temperature°C5 / 35
Max. ambient temperature°C40
pH3 – 11
Heightmm1,650
Widthmm2,550
Depthmm700
Weightkg250
Code no.381 660

For desalination of hardness stabilised water with a salt content of < 1000 mg/l according to German drinking water regulations (free chlorine not detectable). With RO 1000 controller, high pressure pump, frequency controller, concentrate flushing device, connection set for manual cleaning device and preparation for installation of an antiscalant dosing unit.

Tech DataUO2200
Permeate flow ratel/h2200
Min. salt rejection%97
Recovery%75
Operating pressurebar10,0
Membrane element / number4040 / 8
VoltageV/Hz3 x 400/50
Motor powerkW2,2
Feedwater connectionDN32
Permeate/concentrate connectionDN25 / 25
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Min./max. feedwater pressurebar2 / 6
Min./max. feedwater temperature°C5 / 35
Max. ambient temperature°C40
pH3 – 11
Heightmm1,650
Widthmm2,550
Depthmm700
Weightkg330
Code no.381 670

For desalination of hardness stabilised water with a salt content of < 1000 mg/l according to German drinking water regulations (free chlorine not detectable). With RO 1000 controller, high pressure pump, frequency controller, concentrate flushing device, connection set for manual cleaning device and preparation for installation of an antiscalant dosing unit.

Tech DataUOES2500
Permeate flow ratel/h2500
Min. salt rejection%97
Recovery%75
Operating pressurebar10,0
Membrane element / number4040 / 9
VoltageV/Hz3 x 400/50
Motor powerkW2,2
Feedwater connectionDN32
Permeate/concentrate connectionDN25 / 25
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Min./max. feedwater pressurebar2 / 6
Min./max. feedwater temperature°C5 / 35
Max. ambient temperature°C40
pH3 – 11
Heightmm1,650
Widthmm3,550
Depthmm700
Weightkg350
Code no.381 680

For desalination of hardness stabilised water with a salt content of < 1000 mg/l according to German drinking water regulations (free chlorine not detectable). With RO 1000 controller, high pressure pump, frequency controller, concentrate flushing device, connection set for manual cleaning device and preparation for installation of an antiscalant dosing unit.

Tech DataUOES3300
Permeate flow ratel/h3300
Min. salt rejection%97
Recovery%75
Operating pressurebar10,0
Membrane element / number4040 / 12
VoltageV/Hz3 x 400/50
Motor powerkW3,0
Feedwater connectionDN32
Permeate/concentrate connectionDN25 / 25
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Min./max. feedwater pressurebar2 / 6
Min./max. feedwater temperature°C5 / 35
Max. ambient temperature°C40
pH3 – 11
Heightmm1,650
Widthmm3,550
Depthmm700
Weightkg390
Code no.381 690

ES - SERIES 2

Reverse Osmosis ES 3800

AS / FU Series: 3800 – 8000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilised drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.

AS- and AS/FU-systems already contain: Control for metering pump Dosing AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.

Reverse Osmosis – Model ES 3800

AS / FU Series: 3800 – 8000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilized drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.

AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.

Tech DataUOES 3800
Permeate flow ratel/h3,800
Min. salt rejection%97
Recovery%75
Operating pressurebar9,5
Membrane element / number8040 / 3
VoltageV/Hz3 x 400/50
Motor powerkW4,0
Feedwater connectionDN32
Permeate/concentrate connectionDN32 / 32
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Min./max. feedwater pressurebar2 / 6
Min./max. feedwater temperature°C5 / 35
Max. ambient temperature°C40
pH3 – 11
Heightmm1,900
Widthmm2,800
Depthmm750
Weightkg450
Code no.381 700

Reverse Osmosis – Model ES 5000

AS / FU Series: 3800 – 8000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilised drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.

AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.

Tech DataUOES 5000
Permeate flow ratel/h5,000
Min. salt rejection%97
Recovery%75
Operating pressurebar9,5
Membrane element / number8040 / 4
VoltageV/Hz3 x 400/50
Motor powerkW4,0
Feedwater connectionDN40
Permeate/concentrate connectionDN32 / 32
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Min./max. feedwater pressurebar2 / 6
Min./max. feedwater temperature°C5 / 35
Max. ambient temperature°C40
pH3 – 11
Heightmm1,900
Widthmm2,800
Depthmm750
Weightkg500
Code no.381 710

Reverse Osmosis – Model ES 6000

AS / FU Series: 3800 – 8000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilized drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.

AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.

Tech DataUOES 6000
Permeate flow ratel/h6,000
Min. salt rejection%97
Recovery%75
Operating pressurebar9,9
Membrane element / number8040 / 5
VoltageV/Hz3 x 400/50
Motor powerkW4,0
Feedwater connectionDN40
Permeate/concentrate connectionDN40 / 32
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Min./max. feedwater pressurebar2 / 6
Min./max. feedwater temperature°C5 / 35
Max. ambient temperature°C40
pH3 – 11
Heightmm1,900
Widthmm3,800
Depthmm750
Weightkg600
Code no.381 720

Reverse Osmosis – Model ES 7000

AS / FU Series: 3800 – 8000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilized drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.

AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.

Tech DataUOES 7000
Permeate flow ratel/h7,000
Min. salt rejection%97
Recovery%75
Operating pressurebar9,5
Membrane element / number8040 / 6
VoltageV/Hz3 x 400/50
Motor powerkW5,5
Feedwater connectionDN40
Permeate/concentrate connectionDN40 / 32
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Min./max. feedwater pressurebar2 / 6
Min./max. feedwater temperature°C5 / 35
Max. ambient temperature°C40
pH3 – 11
Heightmm1,900
Widthmm3,800
Depthmm750
Weightkg700
Code no.381 730

Reverse Osmosis – Model ES 8000

AS / FU Series: 3800 – 8000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilized drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.

AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.

Tech DataUOES 8000
Permeate flow ratel/h8,000
Min. salt rejection%97
Recovery%75
Operating pressurebar9,5
Membrane element / number8040 / 7
VoltageV/Hz3 x 400/50
Motor powerkW5,5
Feedwater connectionDN50
Permeate/concentrate connectionDN40 / 32
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Min./max. feedwater pressurebar2 / 6
Min./max. feedwater temperature°C5 / 35
Max. ambient temperature°C40
pH3 – 11
Heightmm1,900
Widthmm4,800
Depthmm750
Weightkg800
Code no.381 740

ES - SERIES 3

Reverse Osmosis S3

Reverse Osmosis – ES Series 10,000 to 20,000 l/ph

AS / FU Series: 10000 – 20000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilised drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.

AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.

Reverse Osmosis – Model ES 10,000

AS / FU Series: 10000 – 20000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilised drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.

AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.

Tech DataUOES 10000
Permeate flow ratel/h10000
Min. salt rejection%97
Recovery%75
Operating pressurebar10,0
Membrane element / number8040 / 9
VoltageV/Hz3 x 400/50
Motor powerkW7,5
Feedwater connectionDN50
Permeate/concentrate connectionDN50 / 32
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Min./max. feedwater pressurebar2 / 6
Min./max. feedwater temperature°C5 / 35
Max. ambient temperature°C40
pH3 – 11
Heightmm1,900
Widthmm3,900
Depthmm800
Weightkg900
Code no.381 750

Reverse Osmosis – Model ES 12,000

AS / FU Series: 10000 – 20000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilised drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.

AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.

Tech DataUOES 12000
Permeate flow ratel/h12000
Min. salt rejection%97
Recovery%75
Operating pressurebar9,0
Membrane element / number8040 / 10
VoltageV/Hz3 x 400/50
Motor powerkW7,5
Feedwater connectionDN50
Permeate/concentrate connectionDN50 / 50
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Min./max. feedwater pressurebar2 / 6
Min./max. feedwater temperature°C5 / 35
Max. ambient temperature°C40
pH3 – 11
Heightmm1,900
Widthmm4,900
Depthmm800
Weightkg1,000
Code no.381 760

Reverse Osmosis – Model ES 15,000

AS / FU Series: 10000 – 20000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilized drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.

AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.

Tech DataUOES 15000
Permeate flow ratel/h15000
Min. salt rejection%97
Recovery%75
Operating pressurebar9,5
Membrane element / number8040 / 12
VoltageV/Hz3 x 400/50
Motor powerkW11,0
Feedwater connectionDN65
Permeate/concentrate connectionDN65 / 50
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Min./max. feedwater pressurebar2 / 6
Min./max. feedwater temperature°C5 / 35
Max. ambient temperature°C40
pH3 – 11
Heightmm1,900
Widthmm4,900
Depthmm800
Weightkg1,100
Code no.381 770

Reverse Osmosis – Model ES 18,000

AS / FU Series: 10000 – 20000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilized drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.

AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.

Tech DataUOES 18000
Permeate flow ratel/h18000
Min. salt rejection%97
Recovery%75
Operating pressurebar9,5
Membrane element / number8040 / 15
VoltageV/Hz3 x 400/50
Motor powerkW11,0
Feedwater connectionDN65
Permeate/concentrate connectionDN65 / 50
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Min./max. feedwater pressurebar2 / 6
Min./max. feedwater temperature°C5 / 35
Max. ambient temperature°C40
pH3 – 11
Heightmm1,900
Widthmm5,900
Depthmm800
Weightkg1,300
Code no.381 780

Reverse Osmosis – Model ES 20,000

AS / FU Series: 10000 – 20000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilised drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.

AS- and AS/FU-systems already contain: Control for metering pump Dosin AS-K Concentrate flushing device KSE Preparation for injection point Connection Set for manual cleaning.

Tech DataUOES 20000
Permeate flow ratel/h20000
Min. salt rejection%97
Recovery%75
Operating pressurebar9,0
Membrane element / number8040 / 17
VoltageV/Hz3 x 400/50
Motor powerkW11,0
Feedwater connectionDN65
Permeate/concentrate connectionDN65 / 50
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Min./max. feedwater pressurebar2 / 6
Min./max. feedwater temperature°C5 / 35
Max. ambient temperature°C40
pH3 – 11
Heightmm2,200
Widthmm4,900
Depthmm800
Weightkg1,500
Code no.381 790

ES - SERIES 4

Reverse Osmosis ES Series 4

AS / FU Series: 25000 – 30000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilised drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.

Reverse Osmosis – Model ES 25000

AS / FU Series: 25000 – 30000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilised drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.

Tech DataUOES 25000
Permeate flow ratel/h25000
Min. salt rejection%97
Recovery%75
Operating pressurebar9.5
Membrane element / number8040 / 20
VoltageV/Hz3 x 400/50
Motor powerkW15.0
Feedwater connectionDN80
Permeate/concentrate connectionDN65 / 50
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Min./max. feedwater pressurebar2 / 6
Min./max. feedwater temperature°C5 / 35
Max. ambient temperature°C40
pH3 – 11
Heightmm2,200
Widthmm4,900
Depthmm1,000
Weightkg1,700
Code no.381 800

Reverse Osmosis – Model ES 30,000

AS / FU Series: 25000 – 30000 l/h Antiscalant-based Low Pressure RO systems. Low energy consumption with frequency controlled pump (AS/FU): savings potential up to 30% Low pressure systems for desalination of hardness stabilised drinking water (by antiscalant dosing) with a salt content of < 1000 mg/l. With RO 1000 and horizontal 8“ modules.

Tech DataUOES 30000
Permeate flow ratel/h30000
Min. salt rejection%97
Recovery%75
Operating pressurebar9.5
Membrane element / number8040 / 25
VoltageV/Hz3 x 400/50
Motor powerkW18.5
Feedwater connectionDN100
Permeate/concentrate connectionDN80 / 65
Dosing point connectionR½"
Conductivity rangeμS/cm2 – 200
Min./max. feedwater pressurebar2 / 6
Min./max. feedwater temperature°C5 / 35
Max. ambient temperature°C40
pH3 – 11
Heightmm2,200
Widthmm5,900
Depthmm1,000
Weightkg2,000
Code no.381 810

Herco ES Range

For desalination of hardness stabilised water with a salt content of < 1000 mg/l according to German drinking water regulations (free chlorine not detectable). With RO 1000 controller, high pressure pump, frequency controller, concentrate flushing device, connection set for manual cleaning device and preparation for installation of an antiscalant dosing unit.