You are here : Home | Products & Systems | Water Softeners | DuplexClack Duplex | WS1 TT | Technical Data


 

Water Softeners – Clack Duplex WS1 TT Technical Data

 

Bullet PointSolid state microprocessor with easy access front panel settings
Bullet PointThree modes of operation; meter immediate, meter delayed, or time clock delayed
Bullet PointDouble backwash feature offers optimum regeneration, cleaning ability, and efficiency
Bullet PointCapable of 36 pre-programmed regeneration cycles based on control valve setting
Bullet PointDays override feature; 1 – 28 days available
Bullet PointBackwash and brining ability to 21” diameter tanks
Bullet PointDownflow/upflow regeneration
Bullet PointStores system configuration and operation data in nonvolatile memory
Bullet PointCoin Cell Lithium battery back-up with an 8 hour carry over
Bullet Point12-volt output AC Adapter provides safe and easy installation
Bullet PointControl valve design provides optimum service and backwash rates
Bullet PointPre or Post treated water regenerant refill
Bullet PointPatented one piece expanding seal spacer stack assembly U.S. Patent 6,402,944
Bullet PointPatented linearly reciprocating piston operation U.S. Patent 6,444,127
Bullet PointReliable and proven DC drive

 

Inlet/Outlet Fittings¾" to 1.5” NPS
Cyclesup to 6
Valve MaterialNoryl (1) or equivalent
Regenerationdownflow/upflow
FLOW RATES
Service @15 psi drop (includes bypass and meter)27 gpm
Backwash @ 25 psi drop (includes bypass)27 gpm
Cv Service7.0
Cv Backwash5.4
OPERATING PRESSURES
Minimum/Maximum20 psi – 125 psi
OPERATING TEMPERATURES
Minimum/Maximum40º – 110º F
METER
Accuracy± 5%
Flow Rate Range0.25 – 27 gpm
Gallon Range20 – 50,000 gallons
Totalizer1000 - 9,999,000 gallons
DIMENSIONS & WEIGHT
Distributor Pilot1.050" OD Pipe (¾" NPS)
Drain Line¾” or 1” NPT
Brine Line3/8” or ½” OD Poly Tube
Mounting Base2 ½” - 8 NPSM
Height From Top Of Tank7 3/8”
Weight4.5 lbs
ELECTRICAL SPECIFICATIONS
Supply Voltage230V AC
Supply Frequency50 Hz
Output Voltage12V AC
Output Current500 mA
TANK APPLICATIONS
Water Softener6” – 21” diameter
Water Filter (2)6” – 21” diameter
CYCLES OF OPERATION (Softener Downflow)
CycleRange of times minutes
1. Backwash 1st (upflow)6 - 12
2. Regenerate Draw/Slow Rinse (downflow)45 - 75
3. Backwash 2nd (upflow)3 - 12
4. Fast Rinse (downflow)3 - 8
5. Regenerant Refill (in service with treated water)As Programmed
6. Service (downflow)