herco rs & rse range ro water filters

herco combi simplex

Reverse Osmosis Combi Duplex Series 100 - 500

Combi Simplex Series 50 – 500 l/h Compact RO System with Single Water Softener.

Stand-type unit for desalination of softened drinking water according to German drinking water regulations (free chlorine not detectable), operating on the principle of reverse osmosis. These units include the water pre-treatment components.

Stainless steel base frame with plastic front panel housing the instruments and controls. Prefilter with 100 μm-filter cartridge and 2 pressure gauges, pipe separator (EA1) according to DIN 1988 part 4, softener, compact design, hardness monitoring unit limitron for continuously monitoring of feed water hardness.

Combi S50 Technical Data
Permeate flow ratel/h50
Min. salt rejection%97
Recovery%75
Operating pressurebar14
Membrane element / number2540 / 1
VoltageV/Hz230 / 50
Motor powerkW0.3
Pre-fusingA16
Feedwater connectionDN20
Permeate / concentrate connectionDN10/50
Conductivity rangeμS/cm1 – 99
Min. / max. feed water pressurebar3 / 6
Min. / max. feed water temp °C5 / 35
Max. ambient temperature°C40
pH3 – 11
Capacity of softener°dH x m360
mol x m310.7
Salt stockkg75
Heightmm1700
Widthmm760
Depthmm700
Weight approxca. kg130
Code noS1-420077
Combi S100 Technical Data
Permeate flow ratel/h100
Min. salt rejection%97
Recovery%75
Operating pressurebar12
Membrane element / number2540 / 1
VoltageV/Hz230 / 50
Motor powerkW0.55
Pre-fusingA16
Feedwater connectionDN20
Permeate / concentrate connectionDN10/50
Conductivity rangeμS/cm1 – 99
Min. / max. feed water pressurebar3 / 6
Min. / max. feed water temp °C5 / 35
Max. ambient temperature°C40
pH3 – 11
Capacity of softener°dH x m3120
mol x m321.4
Salt stockkg60
Heightmm1700
Widthmm760
Depthmm700
Weight approxca. kg135
Code noS1-420078
Combi S300 Technical Data
Permeate flow ratel/h300
Min. salt rejection%97
Recovery%75
Operating pressurebar11
Membrane element / number4040 / 1
VoltageV/Hz230 / 50
Motor powerkW0.55
Pre-fusingA16
Feedwater connectionDN20
Permeate / concentrate connectionDN10/50
Conductivity rangeμS/cm1 – 99
Min. / max. feed water pressurebar3 / 6
Min. / max. feed water temp °C5 / 35
Max. ambient temperature°C40
pH3 – 11
Capacity of softener°dH x m3120
mol x m321.4
Salt stockkg60
Heightmm1700
Widthmm760
Depthmm700
Weight approxca. kg142
Code noS1-420117
Combi S300 Technical Data
Permeate flow ratel/h300
Min. salt rejection%97
Recovery%75
Operating pressurebar11
Membrane element / number4040 / 1
VoltageV/Hz230 / 50
Motor powerkW0.55
Pre-fusingA16
Feedwater connectionDN20
Permeate / concentrate connectionDN10/50
Conductivity rangeμS/cm1 – 99
Min. / max. feed water pressurebar3 / 6
Min. / max. feed water temp °C5 / 35
Max. ambient temperature°C40
pH3 – 11
Capacity of softener°dH x m3120
mol x m321.4
Salt stockkg60
Heightmm1700
Widthmm760
Depthmm700
Weight approxca. kg142
Code noS1-420117
Combi S400 Technical Data
Permeate flow ratel/h400
Min. salt rejection%97
Recovery%75
Operating pressurebar10
Membrane element / number4040 / 2
VoltageV/Hz230 / 50
Motor powerkW0.55
Pre-fusingA16
Feedwater connectionDN20
Permeate / concentrate connectionDN10/50
Conductivity rangeμS/cm1 – 99
Min. / max. feed water pressurebar3 / 6
Min. / max. feed water temp °C5 / 35
Max. ambient temperature°C40
pH3 – 11
Capacity of softener°dH x m3120
mol x m321.4
Salt stockkg60
Heightmm1700
Widthmm760
Depthmm700
Weight approxca. kg155
Code noS1-420076
Combi S500 Technical Data
Permeate flow ratel/h500
Min. salt rejection%97
Recovery%75
Operating pressurebar10
Membrane element / number4040 / 2
VoltageV/Hz230 / 50
Motor powerkW0.55
Pre-fusingA16
Feedwater connectionDN20
Permeate / concentrate connectionDN10/50
Conductivity rangeμS/cm1 – 99
Min. / max. feed water pressurebar3 / 6
Min. / max. feed water temp °C5 / 35
Max. ambient temperature°C40
pH3 – 11
Capacity of softener°dH x m3120
mol x m321.4
Salt stockkg60
Heightmm1700
Widthmm760
Depthmm700
Weight approxca. kg157
Code noS1-420121

Description

Stainless steel base frame with plastic front panel housing the instruments and controls. Prefilter with 100 μm-filter cartridge and 2 pressure gauges, pipe separator (EA1) according to DIN 1988 part 4, softener, compact design, hardness monitoring unit limitron for continuously monitoring of feed water hardness, in case of hard water the reverse osmosis shuts-down, special inlet filter, polypropylene with 5 μm- filter cartridge and 2 pressure gauges, high pressure pump, rotary-vane type, high performance wound module with PA/PS composite membranes in GRP pressure vessel with inliner. Valves and instruments including feed water sampling valve, solenoid inlet valve, feed water pressure switch, permeate and concentrate flow meter, vibration-resistant pressure gauges for pump and concentrate pressure, stainless steel valves for adjustment of permeate and concentrate flow rate and concentrate recirculation. Microprocessor control system, as described below, connecting cable (3 m) with 16A – 6h CEE three-pole plug. Unit completely wired and pre-assembled and ready for installation. Electrical equipment in accordance with VDE 0100 part 600, VDE 113 part 1.

RO 500 microprocessor control system

For fully automated monitoring and control of the reverse osmosis unit with two-digit alphanumeric display of permeate conductivity, forced stop and full tank, malfunction signals: low pressure, hard water and high conductivity, LEDs for operation and disinfection, inputs (low voltage) for level control with 1 or 2 float switches, hardness monitoring unit (the RO 500 controller includes control functions for the limitron hardness monitoring unit), shut downs by external signal (forced stop, regeneration), outputs for softening unit (230V/50 Hz) and DDC (collective malfunction signal on floating changeover contact). The units are designed for a maximum TDS of 1,000 mg/l, a water temperature of 15°C, a maximum colloidal index of 3 and free permeate outlet. Under these conditions, the units sill reach design permeate flow after three years of operation. With new units the working pressure is about 15 % lower. The permeate recovery depends on the raw water quality and the type of pre-treatment.

herco combi duplex

Combi Duplex Series Reverse Osmosis Water Filter

Combi Duplex Series – 100 – 500 l/h Compact RO System with Duplex Water Softener.

Stand-type unit for desalination of drinking water according to German drinking water regulations (free chlorine not detectable), operating on the principle of reverse osmosis. These units include the water pre treatment components. Stand-type unit with RO 500 controller, incl. prefilter, pipe separator, duplex softener and limitron.

Combi Combi D100 Technical Data
Permeate flow ratel/h100
Min. salt rejection%97
Recovery%75
Operating pressurebar14
Membrane element / number2540 / 1
VoltageV/Hz230 / 50
Motor powerkW0.55
Pre-fusingA16
Feedwater connectionDN20
Permeate / concentrate connectionDN10/50
Conductivity rangeμS/cm1 – 99
Min. / max. feed water pressurebar3 / 6
Min. / max. feed water temp °C5 / 35
Max. ambient temperature°C40
pH3 – 11
Raw water hardness max.*°dH45
Salt stockkg36
Heightmm1700
Widthmm760
Depthmm700
Weight approxca. kg135
Code noS1-420109
Combi Combi D300 Technical Data
Permeate flow ratel/h300
Min. salt rejection%97
Recovery%75
Operating pressurebar11
Membrane element / number4040 / 1
VoltageV/Hz230 / 50
Motor powerkW0.55
Pre-fusingA16
Feedwater connectionDN20
Permeate / concentrate connectionDN10/50
Conductivity rangeμS/cm1 – 99
Min. / max. feed water pressurebar3 / 6
Min. / max. feed water temp °C5 / 35
Max. ambient temperature°C40
pH3 – 11
Raw water hardness max.*°dH26
Salt stockkg36
Heightmm1700
Widthmm760
Depthmm700
Weight approxca. kg142
Code noS1-420118
Combi Combi D300 Technical Data
Permeate flow ratel/h300
Min. salt rejection%97
Recovery%75
Operating pressurebar11
Membrane element / number4040 / 1
VoltageV/Hz230 / 50
Motor powerkW0.55
Pre-fusingA16
Feedwater connectionDN20
Permeate / concentrate connectionDN10/50
Conductivity rangeμS/cm1 – 99
Min. / max. feed water pressurebar3 / 6
Min. / max. feed water temp °C5 / 35
Max. ambient temperature°C40
pH3 – 11
Raw water hardness max.*°dH26
Salt stockkg36
Heightmm1700
Widthmm760
Depthmm700
Weight approxca. kg142
Code noS1-420118
Combi Combi D400 Technical Data
Permeate flow ratel/h400
Min. salt rejection%97
Recovery%75
Operating pressurebar10
Membrane element / number4040 / 2
VoltageV/Hz230 / 50
Motor powerkW0.55
Pre-fusingA16
Feedwater connectionDN20
Permeate / concentrate connectionDN10/50
Conductivity rangeμS/cm1 – 99
Min. / max. feed water pressurebar3 / 6
Min. / max. feed water temp °C5 / 35
Max. ambient temperature°C40
pH3 – 11
Raw water hardness max.*°dH26
Salt stockkg36
Heightmm1700
Widthmm760
Depthmm700
Weight approxca. kg155
Code noS1-420076
Combi Combi D500 Technical Data
Permeate flow ratel/h500
Min. salt rejection%97
Recovery%75
Operating pressurebar10
Membrane element / number4040 / 2
VoltageV/Hz230 / 50
Motor powerkW0.55
Pre-fusingA16
Feedwater connectionDN20
Permeate / concentrate connectionDN10/50
Conductivity rangeμS/cm1 – 99
Min. / max. feed water pressurebar3 / 6
Min. / max. feed water temp °C5 / 35
Max. ambient temperature°C40
pH3 – 11
Raw water hardness max.*°dH26
Salt stockkg36
Heightmm1700
Widthmm760
Depthmm700
Weight approxca. kg157
Code noS1-420121

Description

Stainless steel base frame with plastic front panel housing the instruments and controls. Prefilter with 100 μm-filter cartridge and 2 pressure gauges, pipe separator (EA1) according to DIN 1988 part 4, duplex softener, compact design, hardness monitoring unit limitron for continuously monitoring feed water hardness, in case of hard water the reverse osmosis shuts-down, special inlet filter, polypropylene with 5 μm-filter cartridge and 2 pressure gauges, high pressure pump, rotary-vane type, high performance wound module with PA/PS composite membranes in GRP pressure vessel with inliner. Valves and instruments including feed water sampling valve, solenoid inlet valve, feed water pressure switch, permeate and concentrate flow meter, vibration-resistant pressure gauges for pump and concentrate pressure, stainless steel valves for adjustment of permeate and concentrate flow rate. Microprocessor control system, as described below, connecting cable (3 m) with 16A – 6h CEE three-pole plug. Unit completely wired and pre-assembled and ready for installation. Electrical equipment in accordance with VDE 0100 part 600, VDE 113 part 1.

RO 500 microprocessor control system

For fully automated monitoring and control of the reverse osmosis unit with two-digit alphanumeric display of permeate conductivity, forced stop and full tank, malfunction signals: low pressure, hard water and high conductivity, LEDs for operation and disinfection, inputs (low voltage) for level control with 1 or 2 float switches, hardness monitoring unit (the RO 500 controller includes control functions for the limitron hardness monitoring unit), shut-downs by external signal (forced stop, regeneration), outputs for softening unit (230 V / 50 Hz) and DDC (collective malfunction signal on floating changeover contact). The units are designed for a maximum TDS of 1,000 mg/l, a water temperature of 15°C, a maximum colloidal index of 3 and free permeate outlet. Under these conditions, the units sill reach design permeate flow after three years of operation. With new units the working pressure is about 15 % lower. The permeate recovery depends on the raw water quality and the type of pre-treatment.

Herco Combi Range

Combi Single Series – 50 – 500 l/h Compact RO System with Single Water Softener.

Combi Duplex Series – 100 – 500 l/h Compact RO System with Duplex Water Softener.

Stand-type unit for desalination of drinking water according to German drinking water regulations (free chlorine not detectable), operating on the principle of reverse osmosis. These units include the water pre treatment components.

Need Help?

Unsure if reverse osmosis filtration is suitable for your requirements?

Contact our technical team for advice :

01629 363311

we are more than happy to help.