You are here : Home | Spares & Parts | Controllers | Reverse Osmosis Controllers | OS3050/51
Reverse Osmosis Controllers – OS3050/51
MODEL SELECTION | |||
OS3015 | OS3020 | ||
OS3030 | OS3050/51 | ||
RGS3000 | RGS8000 |
Reverse Osmosis Controller – OS3050/51
[one_half padding=”0 10px 0 0″][su_note note_color=”#7e7e7e” radius=”10″]Download Manual[/su_note][/one_half] [one_half_last padding=”0 0px 0 0″][/one_half_last] [su_spacer size=”30″]
Reverse Osmosis Controller – OS3050/1 (1 conductivity meter, man. Temp. Comp. 7 inputs and 7 outputs). | |
Model | Power in / out |
OS3050/1 | 24/24, 115/115 or 230/230 VAC |
Reverse Osmosis Controller – OS3050/2 (1 conductivity meter, man. Temp. Comp. 7 inputs and 7 outputs). | |
OS3050/2 | 24/24, 115/115 or 230/230 VAC |
Reverse Osmosis Controller – OS3050/1/l (as OS3050/1 and including 2 recorder outputs ). | |
OS3050/1/1 | 24/24, 115/115 or 230/230 VAC |
Reverse Osmosis Controller – OS3050/2/l (as OS3050/2 and including 2 recorder outputs ). | |
OS3050/2/l | 24/24, 115/115 or 230/230 VAC |
Reverse Osmosis Controller – OS3051/1 (1 conductivity meter, man. Temp. Comp. 7 inputs and 7 outputs). | |
OS3051/1 | 24/24, 115/115 or 230/230 VAC |
Reverse Osmosis Controller – OS3051/2 (2 conductivity meter, aut. Temp. Comp. 7 inputs and 7 outputs). | |
OS3051/2 | 24/24, 115/115 or 230/230 VAC |
Reverse Osmosis Controller – OS3051/1/1 (As OS3051/1 and including 2 recorder outputs). | |
OS3051/1/1 | 24/24, 115/115 or 230/230 VAC |
Reverse Osmosis Controller – OS3051/2/l (As OS3051/2 and including 2 recorder outputs). | |
OS3051/2/l | 24/24, 115/115 or 230/230 VAC |
Description
The unit type OS3050 or type OS3051 is universal applicable for automatic monitoring and control of reverse osmosis plants. The controller is equipped with a conductivity meter optional is a second conductivity meter and temperature meter. Also optional is a circuit board with two recorder outputs (0(4) – 20 mA). There are five possible stages : “Stand by”, “Production”, “Rinse after production”, “Rinse during standby” and “Maintenance”. Adaptable to user specific requirements by built-in programmable options. The programmed configuration will be stored into non volatile memory and therefore not be affected by power loss.
Features
- Menu driven programming utilising “two line” LCD-display
- Choice of languages (English, French, German, Italian, Spanish or Dutch)
- Adaptable to user specific requirements by built-in programmable options.
- Simple control utilising easy to follow symbols.
- Universally applicable for various sizes of installation
- Desalinated water production controllable by hand or level switches
- Control of the maintenance situation by means of a code choice possible
- Programming a service telephone number possible
- Substantial status information employing INFO key: actual input and output conditions, service telephone number, software version, programming situation of the annunciation and malfunction relays, rinse interval, rinse times, instrument probe cell constants
- Large green LED-display showing permeate- and raw water conductivity plus the relative
- Permeate-conductivity as a percentage value of the raw water conductivity or raw water temperature
- Optional card for 2 recorder outputs 0(4)-20mA (conductivity / temperature)
- Input: production-stop, storage tank full/empty, excess pressure, low pressure, concentrate-monitoring or alarm reset, motor protection switch, temperature feeler (optional)
- Integrated conductivity meter with automatic range switching
- Conductivity range according to the instrument probe cell constants from 0,1 to 1 00 000 µS/cm
- The instrument probe cell constants programmable from 0,01 to 10,00 cm-1
- Manual or automatic temperature compensation
- Duplicate conductivity meter and temperature reading as an available option
- Thermo switch with annunciation contact for 115/230 Volt pressure pump as available option Output: pressure pump (protection), input valve, rinse valve for concentrate and permeate, annunciation and malfunction contact
- Security of program information against supply failure, as all program information is stored without accu
- Large capacity microprocessor with “Watchdog”, illegal “Operation code” and frequency monitoring
- Manufactured in accordance with EMC codes of practice; by means of galvanic isolation between the micro-processor and the in- and output circuits, plus extra built-in filter
- Available for wall-mounting and panel-mounting
- Available (input /output) : 24/24V, 115/115V, 230/230V