You are here : Home | Products & Systems | Reverse Osmosis | Herco Range | Soft Water Feed | UP Series | Series 1 | UP 800
Reverse Osmosis – Model UP 800
Reverse Osmosis – Model UP 800
UP Series 1 RO + EDI Systems for ultra-pure water 550 – 1350 l/h
Vertical frame system for desalination of softened drinking water operating on the principle of reverse osmosis (RO) in conjunction with the electro-deionisation method (EDI).
For desalination of softened drinking water according to German drinking water regulations (free chlorine not detectable), operating on the principle of reverse osmosis. Drinking water can also be desalinated without pre treatment. However, in this case the recovery rate is reduced. The decisive factor is the water analysis.
Tech Data | UO | UP800 |
Permeate flow rate | l/h | 550 |
Resistivity EDI product (with free CO2) | MΩ x cm | 5 |
Resistivity EDI product (without free CO2) | MΩ x cm | > 10 |
Recovery | % | 70 |
Operating pressure | bar | 15 |
Membrane element / number | 4040 / 3 | |
Voltage | V/Hz | 3 x 400/50 |
Power consumption | kW | 4,1 |
Max. pre-fusing | A | 16 |
Feed water connection | DN | 25 |
Waste water connection | HT | 50 |
Product water connection | DN | 20 |
Min./max. feed water pressure | bar | 2 / 6 |
Min./max. feed water temperature | °C | 5 / 35 |
Min./max pH value feed water | 5,0 / 9,5 | |
Max. ambient temperature | °C | 40 |
Height | mm | 1,950 |
Width | mm | 1,300 |
Depth | mm | 850 |
Weight approx | kg | 230 |
Code no | 425012 |