[su_spacer size=”400″]IWE Reverse Osmosis – Compact IBC Range Technical Data
Compact IBC Range | Compact IBC Range Technical Data |
Permeate flow rate | l/h | 150 |
Min. salt rejection | % | 95 |
Recovery | % | Up to 80 |
Operating pressure | bar | 10.0 |
Membrane element / number | 4021/1 | |
Voltage | V/Hz | 230/50 |
Motor power | kW | 0.4 |
Pre-fusing | A | 2.5 |
Feedwater connection | R | ¾'' AG |
Permeate/concentrate connection | DN | 10 |
Conductivity range | μS/cm | 1 – 99 |
Min. / max. feed water pressure | bar | 3 / 6 |
Min. / max. feed water temp | °C | 5 / 35 |
Max. ambient temperature | °C | 40 |
pH | 3 – 11 | |
Height | mm | 1600 |
Width | mm | 1200 |
Depth | mm | 1000 |
Weight approx | ca. kg | 480 |