Cooling Tower Controller – AS3050/1
Cooling Tower Controller – AS3050/1 Wall Mounted (1 conductivity meter, man. Temp. Comp. 7 inputs and 7 outputs). | |
Model | Power in / out |
AS3050/1 | 24/24, 115/115 or 230/230 VAC |
Cooling Tower Controller – AS3050/2 Wall Mounted (2 conductivity meter, auto. Temp. Comp. 7 inputs and 7 outputs). | |
AS3050/2 | 24/24, 115/115 or 230/230 VAC |
Cooling Tower Controller – AS3050/1/l Wall Mounted (As AS3050/1 and including 2 recorder outputs). | |
AS3050/1/l | 24/24, 115/115 or 230/230 VAC |
Cooling Tower Controller – AS3050/2/l Wall Mounted (As AS3050/2 and including 2 recorder outputs). | |
AS3050/2/l | 24/24, 115/115 or 230/230 VAC |
Cooling Tower Controller – AS3051/1 Panel Mounted (1 conductivity meter, man. Temp. Comp. 7 inputs and 7 outputs). | |
AS3051/1 | 24/24, 115/115 or 230/230 VAC |
Cooling Tower Controller – AS3051/2 Panel Mounted (2 conductivity meter, auto. Temp. Comp. 7 inputs and 7 outputs). | |
AS3051/2 | 24/24, 115/115 or 230/230 VAC |
Cooling Tower Controller – AS3051/1/1 Panel Mounted (As AS3051/1 and including 2 recorder outputs). | |
AS3051/1/1 | 24/24, 115/115 or 230/230 VAC |
Cooling Tower Controller – AS3051/2/l Panel Mounted (As AS3051/2 and including 2 recorder outputs). | |
AS3051/2/l | 24/24, 115/115 or 230/230 VAC |
- Menu driven programming utilising “two line” LCD-display
- Choice of languages (English, French, German or Dutch)
- Adaptable to user specific requirements by built-in programmable options
- Simple control utilising easy to follow symbols
- Universally applicable for various sizes of installation
- Programming a service telephone number possible
- Substantial status information employing INFO key:
- actual input and output conditions
- service telephone number
- software version
- programming situation of the annunciation and malfunction relays
- instrument probe cell constants
- Large green LCD-display showing water conductivity
- 7 Inputs : low level 1, tank full, tank empty, flush blocking 1, fluch blocking 2, low level 2, water meter
- 3 relay outputs (powered) : flush valve 1, flush valve 2, inlet valve
- 3 relay outputs (dry contact) : dosing output 1, dosing output 2, alarm
- Integrated conductivity meter with automatic range switching
- Conductivity range according to the instrument probe cell constants from 0,1 to 1 00 000 µS/cm
- The instrument probe cell constants programmable from 0,01 to 10,00 cm-1
- Manual or automatic temperature compensation
- Duplicate conductivity meter and temperature reading as an available option
- Second cooling tower plant possible when card with two conductivity meters is installed.
- Status of second cooling tower control only in LCD display (not with LEDs)
- Security of program information against supply failure, as all program information is stored without accu
- Large capacity microprocessor with “Watchdog”, illegal “Operation code” and frequency monitoring
- Manufactured in accordance with EMC codes of practice;
- by means of galvanic isolation between the micro-processor and the in- and output circuits, plus extra built-in filter
- Available for wall mounting (AS3050) and panel-mounting (AS3051)
- Available (input /output) : 24/24V, 115/115V, 230/230V