Reverse Osmosis Controller – OS3050/1 (1 conductivity meter, man. Temp. Comp. 7 inputs and 7 outputs). | |
Model | Power in / out |
OS3050/1 | 24/24, 115/115 or 230/230 VAC |
Reverse Osmosis Controller – OS3050/2 (1 conductivity meter, man. Temp. Comp. 7 inputs and 7 outputs). | |
OS3050/2 | 24/24, 115/115 or 230/230 VAC |
Reverse Osmosis Controller – OS3050/1/l (as OS3050/1 and including 2 recorder outputs ). | |
OS3050/1/1 | 24/24, 115/115 or 230/230 VAC |
Reverse Osmosis Controller – OS3050/2/l (as OS3050/2 and including 2 recorder outputs ). | |
OS3050/2/l | 24/24, 115/115 or 230/230 VAC |
Reverse Osmosis Controller – OS3051/1 (1 conductivity meter, man. Temp. Comp. 7 inputs and 7 outputs). | |
OS3051/1 | 24/24, 115/115 or 230/230 VAC |
Reverse Osmosis Controller – OS3051/2 (2 conductivity meter, aut. Temp. Comp. 7 inputs and 7 outputs). | |
OS3051/2 | 24/24, 115/115 or 230/230 VAC |
Reverse Osmosis Controller – OS3051/1/1 (As OS3051/1 and including 2 recorder outputs). | |
OS3051/1/1 | 24/24, 115/115 or 230/230 VAC |
Reverse Osmosis Controller – OS3051/2/l (As OS3051/2 and including 2 recorder outputs). | |
OS3051/2/l | 24/24, 115/115 or 230/230 VAC |
Reverse Osmosis Controller – OS3050/3051
- Menu driven programming utilising “two line” LCD-display.
- Choice of languages (English, French, German, Italian, Spanish or Dutch).
- Adaptable to user specific requirements by built-in programmable options.
- Simple control utilising easy to follow symbols.
- Universally applicable for various sizes of installation.
- Desalinated water production controllable by hand or level switches.
- Control of the maintenance situation by means of a code choice possible.
- Programming a service telephone number possible.
- Substantial status information employing INFO key: actual input and output conditions, service telephone number, software version, programming situation of the annunciation and malfunction relays, rinse interval, rinse times, instrument probe cell constants.
- Large green LED-display showing permeate- and raw water conductivity plus the relative.
- Permeate-conductivity as a percentage value of the raw water conductivity or raw water temperature.
- Optional card for 2 recorder outputs 0(4)-20mA (conductivity / temperature).
- Input: production-stop, storage tank full/empty, excess pressure, low pressure, concentrate-monitoring or alarm reset, motor protection switch, temperature feeler (optional).
- Integrated conductivity meter with automatic range switching.
- Conductivity range according to the instrument probe cell constants from 0,1 to 1 00 000 µS/cm.
- The instrument probe cell constants programmable from 0,01 to 10,00 cm-1.
- Manual or automatic temperature compensation.
- Duplicate conductivity meter and temperature reading as an available option.
- Thermo switch with annunciation contact for 115/230 Volt pressure pump as available option Output: pressure pump (protection), input valve, rinse valve for concentrate and permeate, annunciation and malfunction contact.
- Security of program information against supply failure, as all program information is stored without accu.
- Large capacity microprocessor with “Watchdog”, illegal “Operation code” and frequency monitoring.
- Manufactured in accordance with EMC codes of practice; by means of galvanic isolation between the micro-processor and the in- and output circuits, plus extra built-in filter.
- Available for wall-mounting and panel-mounting.
- variable (input /output) : 24/24V, 115/115V, 230/230V.